
Add to Cart
Titanium mirror stainless steel cabin decoration for passenger lift
Type | Ceiling | Cabin wall | Handrail |
SN-CD-488 | Titanium mirror stainless steel, on both sides of the LED light, middle white dome light | Three side of the center plate for the titanium surface of stainless steel, the rest of the titanium hairline stainless steel | Titanium |
SN-CD-489 | Among threads to steel,white colour steel plate model,hide inside and outside lights | After middle wall white colour modelling,the internal fritillaria hidden lights, wood veneer wall glass mirror,titanium hair around the borders,on the both sides of the wood veneer | Titanium, log armrest |
SN-CD-490 | Sandblasted stainless steel, on both sides of the LED light,middle white acrylic pervious to light | After middle wall mirror etched stainless steel,on both sides of the middle imitation marble tile, the rest of the titanium mirror stainless steel | Titanium |
SN-CD-491 | Around the black mirror stainless steel,titanium | Back wall titanium etch stainless steel,wire frame technology,black titanium stainless steel, process lines,wall black titanium stainless steel,leather bag,process line | Black titanium |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.