
Add to Cart
Observational cabins capsule sightseeing glass passenger elevator
Observation Elevator Cabin
Model | Upper/lower hood | Observation wall | Decoration top | Car wall | Handrail | Floor |
SN-CD-901 | Hailine stainless steel | Safety laminated glass,thickness 6+6 | Mirror stainless steel top panel,acrylic lighting decorationHandrail:St./St.Tube | Hairline stainless steel,safety laminated glass | Stainless steel round tube | PVC floor |
SN-CD-902 | Hailine stainless steel | Safety laminated glass | Steel plate baked enamel | Hairline stainless steel | Floor type | PVC floor |
SN-CD-965 | Painted steel plate | Safety laminated glass | Multi-ply reflection art panel + down lamp | Stainless steel reflection panel | Stainless steel mono-tube | PVC floor |
SN-CD-903 | Painted steel plate + titanium gold stainless steel skirting | 9PCS of safety laminated glass | Multi-ply reflection art panel + down lamp | Stainless steel hairline panel | Stainless steel mono-tube | PVC floor |
SN-CD-962 | Semi-round acrylic crown + steel plate spray lacquer + stainless steel skirting + decoration lamp | 3PCS of safety laminated glass | White ceiling lamp + down lamp | Stainless steel hairline panel | Stainless steel mono-tube | PVC floor |
SN-CD-963 | Hailine stainless steel | 3PCS of safety laminated glass | White ceiling lamp + down lamp | Stainless steel hairline panel | Stainless steel triple tubes | PVC floor |
SN-CD-964 | Painted steel plate + decoration lamp | 3PCS of safety laminated glass | Multi-ply reflection art panel + down lamp | Mirror,etched,hairline,irregular grain | Stainless steel mono-tube | PVC floor |
SN-CD-961 | Painted steel plate + stainless steel skirting + decoration lamp | 3PCS of safety laminated glass | LF-519 ceiling | Hairline,etched | Stainless steel mono-tube | PVC floor |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.